2.0 Prepare Part 2- Evaluate Treatment and Use
Evaluate alternative treatments by discipline
2.1 Discuss and Analyze Ultimate Treatment and Use
- Discuss and analyze the ultimate treatment and use of the structure
as defined in park
planning documents.
- Present alternative approaches
2.1.1 Civil
2.1.1.1 Provide Recommendations for Water System Components
- ist recommendations for existing system repairs/rehabilitation.
- List recommendations for new water system components.
- List recommendations for further analysis, investigation.
2.1.1.2 Provide Recommendations for Wastewater System Components
- List recommendations for existing system repairs/rehabilitation.
- List recommendations for new wastewater system components.
- List recommendations for further analysis, investigation.
2.1.1.3 Provide Recommendations for Motor Vehicle Access and Pedestrian
Access
- List Recommendations for Existing Motor Vehicle Access and Pedestrian Access Repairs/ Rehabilitation
- List Recommendations for New Motor Vehicle Access and
Pedestrian Access
- List Recommendations for Further Analysis, Investigation
2.1.2 Site
2.1.2.1 Provide Recommendations for Site Condition Improvements.
- List recommendations for site drainage and storm sewer
repairs, rehabilitation.
- List recommendations for new site drainage and storm sewer
system components.
- List recommendations regarding site landscaping, vegetation and fencing.
- List recommendations for further analysis, investigation.
2.1.3 Architecture
2.1.3.1 Provide Recommendations Repair / Replacement of the
following Damaged/Deteriorated Elements:
- Existing materials.
- New materials.
- Roofs.
- Additional insulation.
- Increasing slope.
- Raising flashing heights.
- Relocating or remounting rooftop equipment.
- Reconstructing or adding expansion joints.
- Changing roof materials.
- Adding more primary drains or scuppers.
- Adding overflow drains and scuppers.
- Repair or replacement of roof.
- For accessibility.
2.1.3.2 Provide Recommendations for Further Investigation / Analysis
2.1.4 Structural
2.1.4.1 Provide Recommendations for the following:
- Discussion of applicable codes (IEBC, IBC, NFPA, ASC 7, ASCE 31).
- Existing conditions.
- Recommendations for repair/replacement of
damaged/deteriorated elements.
- Load bearing analysis.
- Recommendations for strengthening.
- Recommendations for further investigation/analysis.
2.1.5 Mechanical
2.1.5.1 Provide Recommended Treatments (Suitable Options for Each Mechanical System Should Be Listed Along With Pros and Cons for Each Option)
- Perform code analysis and requirements (including requirements specific
to NPS, e.g., D.O. 58).
2.1.6 Electrical
2.1.6.1 Prepare Recommendations for the Following:
- List recommendations for repair/replacement of electrical systems.
2.1.7 Safety
2.1.7.1 Prepare NPS RM 58 [Structural Fire] compliant Fire Safety
Plan to address the unique fire and life safety issues. The Fire Safety
Plan consists of the following elements:
- INTRODUCTION
- DESIGN TEAM
- APPLICABLE CODES
- FIRE PROTECTION/LIFE SAFETY APPROACH
- General Description
- General Fire Resistive Construction Aspects
- Occupancy Classifications
- Fire Resistive Separations
- Doors and Windows
- Interior Wall, Ceiling and Floor Finishes
- Decorative Structures Within Buildings
- Egress
- Special Design
- Emergency Signage
- Suppression Systems
- Fire Department Access
- Fire Detection and Alarm System
- Emergency Communication Systems
- Smoke Management Description
- Central Control Station
- Emergency and Standby Power
- Elevators
- ACCEPTANCE TESTING
- PERIODIC OPERATION AND MAINTENANCE
- CONCLUSION
2.2 Specify Requirements for Treatment
- Outline compliance requirements to applicable laws, and regulations
surrounding issues of life safety, fire protection, energy conservation,
abatement of hazardous materials, and universal accessibility.
2.3 Specify Alternatives for Treatment
- Present and evaluate alternative approaches to the ultimate treatment
in both narrative and graphic form.
- Prepare Alternatives for Treatment Matrix
- List alternative Treatments with Advantages and Disadvantages,
i.e.:
|
Alternative Treatment
|
Advantages (Beneficial Effects)
|
Disadvantages (Adverse Effects)
|
|
Replace Exposed Roof Rafters
|
Stronger than repair
|
Higher Cost
|
|
Repair Exposed Roof Rafters
|
No loss of historic Fabric, Lower cost
|
Not as strong, structurally
|
- Typical Disciplines:
- Civil
- Site
- Architecture
- Structural
- Mechanical
- Electrical
- Safety
2.4 Specify Assessment of the Effect of
Recommended Treatments
- Prepare Assessment of Effect for Recommended Treatments Matrix.
- Assess recommended treatments and their effect on character-defining
features—qualities that make the structure eligible for the
National Register of Historic Places, i.e.:
|
Recommended Treatment
|
Potential Effects
|
Mitigating Measures
|
Beneficial Effects
|
|
Repair Exposed Roof Rafters
|
Repair will be visible
|
Repair shall be done in such a way that it is less visible
|
No loss of historic Fabric
|
|
Replace Exposed Roof Rafters
|
Loss of historic fabric
|
Replace in-kind with the same species
|
No visible repair
|
- Typical Disciplines:
- Civil
- Site
- Architecture
- Structural
- Mechanical
- Electrical
- Safety
Back to top ^
|